one.2.2 Warning Labels Warning Labels Which means You should cautiously read this handbook in advance of use product. The subsequent labels are a. Don't spot the unit on a sloped area. Normally the offered in the event the procedure device may well slide, leading to personal personal injury or even the product performs Using the cellular malfunction.

The consumer is not really allowed to open up the addresses and panel on the process, neither Notice: system disassemble is allowed. To ensure the system functionality and basic safety, only Mindray engineers or engineers authorized by Mindray can complete routine maintenance.

Get a complete and prolonged watch with the anatomical structure by panoramic imaging coupled with velocity sign and forward/backward scan means producing scanning less of a challenge, smoother and even more controllable.

Tend not to use any cables aside from the cables offered with the machine by Mindray. 3. Use the cable supplied with This technique to connect the printer. Other cables could end in electric shock. Page 15: Mechanical Safety

Cut off cable ties connecting the primary device about the Exhibit by diagonal slicing pliers, after which pull out the corresponding cable plugs.

Mindray’s new era of black & white ultrasound program, DP-fifty Specialist, is provided with State-of-the-art imaging technologies permitting deeper penetration and quicker graphic acquisition with larger resolution.

S. should supply the Section using an e-mail deal with if they have a person. The email messages provided could be used for official interaction With all the licensee. Even so e-mail addresses are public record. If you don't desire to provide a private handle, make sure you give the Division with the electronic mail handle that may be made accessible to the general public. You should see our Chapter 455 web page to determine If you're affected by this change.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits use of a number of scanned angles to sort just one picture, leading to Increased distinction resolution and enhanced visualization

Function: Within the back-finish of the primary board, a Unique check IC is employed to monitor signal voltages  and clock battery energy which can be supplied to the leading board by the leading device box electricity supply module.

Kebutuhan Anda akan alat profesional dan Dp50rb login canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

.. Page 161 The indicator to the printer Mistakes occur in the event the adapter turns orange, as well as the printing printer adapter operates. Disconnect and connect the fails. electrical power adapter, energy around the printer adapter once again, and validate whether or not the printing is ordinary right after one moment. Site 163: Electrical Security Inspection

Effectiveness Take a look at 5.5.one Exam System Resolution Detection depth Geometric Posture Accuracy Blackout area test History the Examination photos 5.5.2 Examination Articles The picture utilized Here's just for reference, persist with the picture outcome in the true Take note: predicament. Needs: Display screen: set the contrast and brightness for the clinical application worth (or even the default status) Procedure natural environment: darkish home, simulating the clinical software setting. Webpage 76 In affliction which the transverse resolution tests targets are horizontally displayed, file the negligible length of two targets that could be Evidently recognized. Repeat the operation previously mentioned with the transverse resolution tests targets at other depths. As revealed in determine down below. Axial resolution ... Webpage 77 When using the convex probe, hold the transverse resolution screening targets to NOTE: be displayed close to the midline. When employing a linear probe with steer function, will not activate the steer purpose when conduct the transverse resolution exam. Zoom during the location wherever the targets Situated if required. The diameter on the goal stage at a specific depth is equal to the transverse resolution at the depth. Page seventy eight 5.

Soon after changing the CPU module, critical file need to be produced Again according to the new MAC deal with and published into HDD in the device. Or else, the configuration function on the item are going to be misplaced. Immediately after removing the CPU module, Take away panhead screws with washers (12 M3X6) fastened on the key unit box, you usually takes from the board. Web page 118 Figure eight-29 Disassemble the User interface Assembly (one) Maintain the upper edge of control panel assembly, and open up up the user interface. Figure 8-thirty Disassemble the User interface Assembly (2) Immediately after eradicating 1 countersunk head self-tapping screw PT3X10 set to the control panel and acquire out the plug with the keyboard and the most crucial device connecting cables, you could possibly take out the control panel assembly.

Be aware: Make sure that you could possibly pull out and force in the IO board sockets vertically when pulling out and assembling the IO board assembly within the posture on the deal with. Remove panhead screws with washers M3X6 (4) used to safe the IO board, after which you can you can take out the IO board. Webpage 116 Take out panhead screws with washers (two M3X6) which can be preset on the principle device, take out the upper baffle and afterwards pull out two cables connecting the primary board to the ability module assembly.